Tripp Lite's Smart Online SU3000XL online, double conversion UPS protects critical server, networking or telecommunications equipment from blackouts, brownouts, voltage fluctuations and surges in an attractive all-black tower format. Large capacity 3kVA/2400 watt UPS continuously converts incoming AC-to-DC, then back to perfect sine wave AC output at 120V AC (+/-2%). Removes harmonic distortion, fast electrical impulses, frequency fluctuations and other hard-to-solve power problems not addressed by other UPS systems. True sine wave output and zero transfer time offers guaranteed compatibility with all equipment types. Includes 9 UPS supported outlets with two individually switchable load banks that can be independently controlled via the UPS's software interface to selectively reboot remote equipment or automatically shed less critical loads to extend battery runtime for the most critical equipment. Battery support can be extended with the addition of multiple external battery packs (part# BP72V18). Support simultaneous communications via HID-compliant USB port, a slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port for unattended shutdown, remote control and monitoring of UPS system and power data. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Inc
|
| Manufacturer |
Tripp Lite |
| Manufacturer Part Number |
SU3000XL |
| Manufacturer Website Address |
www.tripplite.com |
| Brand Name |
Tripp Lite |
| Product Line |
SmartOnline |
| Product Name |
SmartOnline SU3000XL UPS |
| Product Type |
Dual Conversion Online UPS |
| Technical Information | Plug/Connector Type | NEMA L5-30P |
| Receptacles | 6 x NEMA 5-20R 1 x NEMA L5-30R |
|
| Power Description | Load Capacity | 3000VA/2400W |
| Input Voltage | 110V AC |
| Input Voltage Range | 120V AC Single-phase |
| Output Voltage | 120V AC Single-phase |
| Frequency | 50Hz 60Hz |
| Waveform Type | Sine Wave |
| Filtering | EMI / RFI |
|
| Management | Network Management | SNMP Manageable Optional |
| Overload Protection | 2 20A output breakers and 1 40A input breaker |
| Alarm | On Battery Low Battery Overload UPS Fault |
| Emergency Power OFF | Optional |
|
| Controls/Indicators | Status Indicators | 14 STATUS LEDs offer LINE POWER, ONLINE, BYPASS, ON BATTERY, OVERLOAD, BATTERY LOW, REPLACE BATTERY and FAULT status information. Also includes 4 LED meters for LOAD LEVEL / BATTERY LEVEL display (Battery level readout requires pressing "test" key) |
|
| Interfaces/Ports | Interfaces/Ports | 1 x DB-9 |
| Modular Slots | 1 x Communications Slot |
|
| Battery Information | Batteries | Sealed Lead Acid |
| Backup/Run Time | 6 Minute 3000VA Full Load 17 Minute 1500VA Half Load |
| Battery Life | 3 Year to 6 Year |
| Battery Recharge Time | 4 Hour |
|
| Environmental Conditions | Temperature | 32 to 104 Operating |
| Humidity | 0 to 95% Non-condensing Relative Humidity |
|
| Physical Characteristics | Form Factor | Tower |
| Power Cord/Cable | 10 ft |
| Dimensions | 14.75" Height x 5.5" Width x 16.75" Depth |
| Shipping Dimensions | 19.5" Height x 10" Width x 24" Depth |
| Weight | 66 lb |
| Shipping Weight | 73 lb |
|
| Miscellaneous | Package Contents | SmartOnline SU3000XL UPSSU3000XL Online, Double-Conversion UPS SystemPowerAlert Software and cablingInstruction manual with warranty information |
| Additional Information | True on-line, double conversion UPS provides pure, sine wave AC output
Maintains continuous operation through blackouts, brownouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, electrical impulses, frequency variations and other hard to solve power problems
Accepts input voltages between 80 and 138 (65 to 138 at loads under 70%), regulating output to 120V AC +/-2%
3000VA / 2400 watt output capacity with 7 total outlets (6 NEMA 5-15/20R, 1 NEMA L5-30R)
Two built-in individually switchable load banks can be controlled via the UPS's software interface to selectively reboot remote equipment or automatically shed less critical loads to extend battery runtime for the most critical equipment (2 banks of 3 outlets)
Standard internal battery set provides 17 minutes runtime at half load
Expandable runtime with multiple external battery packs (part# BP72V9)
Attractive all-black upright tower format
DB9 serial network interface supports RS-232 and contact closure messaging
Slot for optional SNMP/web card (part# SNMPWEBCARD)
Included PowerAlert UPS Power Management Software and cabling provide monitoring of in-depth site power conditions, full UPS status and fault warnings, output load level and load bank power control
Compatible with Tripp Lite's WatchDog Service Monitoring/Rebooting Software (part# WATCHDOGSW)
Diagnostic LEDs
2 year manufacturer's product warranty
$250,000 Ultimate Lifetime Insurance (USA & Canada only) |
| System Requirements | TYPCICAL APPLICATIONS:
Ideal for protection of critical 120V AC servers, networking equipment and sensitive electronics. Common applications include corporate or departmental servers, workstations, hubs, routers, bridges, CAD/CAM workstations, concentrators, IP telephony and traditional PBX switching systems |
| Certifications & Standards | UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico), Conforms to IEEE 587 / ANSI C62.41 specifications |
|
| Warranty | 2 Year |
|