• Tripp Lite by Eaton 1.9kW Single-Phase Switched PDU, LX Interface, 120V Outlets (8 5-15/20R), NEMA L5-20P/5-20P input, 12 ft. (3.66 m) Cord, 1U Rack, TAA
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Front/500
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Right/500
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Rear/500
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Alternate-Image1/500
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Alternate-Image2/500
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Alternate-Image3/500
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Alternate-Image4/500
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Alternate-Image5/500
  • Tripp Lite by Eaton 1.9kW Single-Phase Switched PDU, LX Interface, 120V Outlets (8 5-15/20R), NEMA L5-20P/5-20P input, 12 ft. (3.66 m) Cord, 1U Rack, TAA
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Front/500
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Right/500
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Rear/500
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Alternate-Image1/500
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Alternate-Image2/500
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Alternate-Image3/500
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Alternate-Image4/500
  • Tripp Lite By Eaton 1.9kW Single Phase Switched PDU, LX Interface, 120V Outlets (8 5 15/20R), NEMA L5 20P/5 20P Input, 12 Ft. (3.66 M) Cord, 1U Rack, TAA Alternate-Image5/500

Shipping Information

The shipping process is fully robotic and orders are normally pulled and shipped quickly in 7 different warehouses across the US and then dropped in sealed USPS, UPS and FedEx containers for pick-up on the next business day. High volume or backordered items may have additional shipping delays. Once pulled, orders cannot be stopped, however you can return orders for refund unopened if you have changed your mind. Tracking normally is sent / updated within 48 hours of pick-up. Delivery is normally 3-10 business days after leaving the warehouse, however carrier delays may occur. Shipping may take longer in rural areas, due to carrier delay, weather or acts of God. Weekends and Holidays do not count as business days and have no pickup, movement or delivery.

Covid 19 Update — We have seen slowdowns and backlogs in package pickup, sorting, scanning and delivery by UPS, Fedex and USPS caused by worker shortages and facilities disruption due to the Covid 19 Pandemic. Some UPS and USPS hubs are no longer scanning all packages, as a result some tracking will show nothing until delivery.

Tripp Lite by Eaton 1.9kW Single-Phase Switched PDU, LX Interface, 120V Outlets (8 5-15/20R), NEMA L5-20P/5-20P input, 12 ft. (3.66 m) Cord, 1U Rack, TAA


MSRP: $860.40
Sale: $529.06
Your Savings: $331.34

$529.06

In Stock
FREE GROUND SHIPPING *


Tripp Lite by Eaton 1.9kW Single-Phase Switched PDU, LX Interface, 120V Outlets (8 5-15/20R), NEMA L5-20P/5-20P input, 12 ft. (3.66 m) Cord, 1U Rack, TAA MFG: Tripp Lite
UPC: 037332203281

  • Switched
  • NEMA L5-20P/5-20P
  • 8 x NEMA 5-15/20R
  • 120 V AC
  • Network (RJ-45)
  • 1U
  • Horizontal
  • Rack Mount
  • Rack-mountable
  • TAA Compliant

* ground shipping normally takes 3-10 business days, depending on destination

Click here to view our Return Policy
Click here to view our full Terms of Sale


Overview

The PDUMH20NET2LX 1.9kW Single-Phase Switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.

The 1U PDU features eight switched NEMA 5-15/20R outlets with an included cord retention bracket to prevent cables from becoming accidentally disconnected. A 12-foot cord with NEMA L5-20P plug and 5-20P plug adapter connects the PDU to a compatible AC power source, generator or protected UPS.

The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

A digital ammeter allows you to monitor the total load in real time to ensure it remains well below maximum capacity with no danger of overload. The single-phase PDU installs in 1U of space in EIA-standard 19-inch racks. You can also mount it vertically in 0U of rack space or on a wall or under a counter with the included brackets and user-supplied screws.

Features

Distributes, Monitors and Manages Network-Grade AC Power

  • 1.9kW 120V switched PDU with single-phase input
  • Recommended for network applications requiring individual outlet control, load shedding and remote monitoring of critical network components
  • NEMA L5-20P plug with 12 ft. cord and 5-20P plug adapter connects to compatible AC power source
  • Firmware upgrades support future product enhancements
  • Digital ammeter reports total PDU load in real time

8 Switched NEMA 5-15/20R Outlets Distribute AC Power

  • Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices
  • Cord retention bracket prevents cables from becoming accidentally disconnected
  • Individual LEDs indicate which outlets are live

Built-In LX Platform Interface

  • Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH
  • Supports 10/100 Mbps auto-sensing for communication with an Ethernet network
  • Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities
  • No Java required

Broad Communications Compatibility

  • Supports IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP
  • Supports automatic and manual assignment of IP address

Essential Safety Features

  • Tiered access allows administrator and guest to log in via web browser
  • Immediate alert notifications via email or SNMP traps
  • Supports user-specified alarm notification thresholds
  • Real-time clock backup maintains day/date even if PDU is unpowered

Flexible Mounting Options

  • Included rack-mounting brackets compatible with front- or rear-facing installation
  • Compatible with 1U horizontal, 0U vertical, wall and under-counter mounting with included brackets and user-supplied screws

Tech Specs

Manufacturer Tripp Lite by Eaton
Manufacturer Part Number PDUMH20NET2LX
Manufacturer Website Address https://tripplite.eaton.com/
Brand Name Tripp Lite by Eaton
Product Model PDUMH20NET2LX
Product Name PDUMH20NET2LX 1.9kW Single-Phase Switched PDU
Product Type PDU
Technical Information:
PDU TypeSwitched
DesignModular
PhaseSingle Phase
Plug/Connector TypeNEMA L5-20P/5-20P
Receptacle TypeNEMA 5-15/20R
Receptacle Detail8 x NEMA 5-15/20R
Power Description:
Input Voltage120 V AC
Output Voltage120 V AC
Power Rating (Watt)1900 W
Input Current20 A
Management:
Management
  • IPv4
  • IPv6
  • HTTP
  • HTTPS
  • SMTP
  • SNMPv1
  • SNMPv2
  • SNMPv3
  • telnet
  • SSH
  • FTP
  • DHCP
  • NTP
Remote Outlet SwitchingYes
Interfaces/Ports:
Network (RJ-45)Yes
Physical Characteristics:
Mounting OrientationHorizontal
Mount TypeRack-mountable
Rack Height1U
Height1.8"
Width17.5"
Depth4.3"
Weight (Approximate)5.99 lb
Miscellaneous:
Package Contents
  • PDUMH20NET2LX 1.9kW Single-Phase Switched PDU
  • Built-In LX Platform Interface
  • Configuration Cable
  • 8 x Cable Ties
  • Cord Retention Bracket
  • Mounting Hardware
  • Owner's Manual
Environmentally FriendlyYes
Country of OriginTaiwan
TAA CompliantYes
Warranty:
Limited Warranty2 Year

Files:
User-Manual
Manufacturer-Brochure

Add To Cart To See Price

The "Add to Cart to See Price" message indicates an additional discount is in effect, and this discount is calculated in the Shopping Cart.

You can see this price by adding this item to your shopping cart.

Please be assured that simply adding an item to your cart does not obligate you to buy it--you can always delete the item from your cart if you decide not to purchase it.